Overview
When a Muse headband with PPG is available alongside camera-based rPPG, the SDK supports sensor fusion — using the contact PPG as a reference to calibrate and improve camera-based heart rate estimates.
MuseFusionCalibrator
Fuses Muse PPG readings with camera rPPG estimates for improved accuracy:
import { RppgProcessor, MuseFusionCalibrator } from "@elata-biosciences/rppg-web";
const processor = new RppgProcessor("wasm", 30);
const calibrator = new MuseFusionCalibrator();
// Feed Muse PPG readings (from headband)
calibrator.updateMuse(museBpm, quality, timestampMs);
// Feed camera rPPG readings
calibrator.updateCamera(cameraBpm, cameraQuality, timestampMs);
// Get fused result
const fused = calibrator.fuse(cameraBpm, cameraQuality, timestampMs);
The RppgProcessor also has a built-in Muse integration:
processor.updateMuseMetrics(museBpm, quality, timestampMs);
MuseCalibrationModel
A simple regression model that learns the relationship between camera and contact BPM over time:
import { MuseCalibrationModel } from "@elata-biosciences/rppg-web";
const model = new MuseCalibrationModel();
// Train with paired observations
model.train(spectralBpm, acfBpm, trueBpm);
// Check if enough data collected
if (model.isTrained()) {
const predictedBpm = model.predict(spectralBpm, acfBpm);
}
// Persistence
const snapshot = model.getSnapshot();
model.loadSnapshot(snapshot);
model.reset();
BPM Evidence Types
The processor produces evidence from multiple analysis methods:
type BpmEvidenceSource = "spectral" | "acf" | "tracker" | "muse" | "calibrated";
type BpmEvidence = {
source: BpmEvidenceSource;
bpm: number;
quality: number;
timestampMs: number;
};
type BpmResolutionResult = {
bpm: number;
quality: number;
source: BpmEvidenceSource;
evidence: BpmEvidence[];
};
type FusionSource = "camera" | "muse" | "fused";
Muse PPG Filter
Apply Muse-style bandpass filtering to PPG samples:
import { museStyleFilter } from "@elata-biosciences/rppg-web";
const filtered = museStyleFilter(ppgSamples, sampleRate);
Calibration Workflow
- Start with camera-only rPPG
- When a Muse headband connects, feed its PPG as ground truth
- The calibration model learns the camera-to-contact mapping
- Once trained, camera-only estimates are corrected using the learned model
- The fusion calibrator combines both sources for maximum accuracy